Trouble type | C5102: Main motor failure to turnC5103: Main motor turning at abnormal timing |
Rank | B |
Trouble detection condition | C5102: The control circuit detects motor failure to turn while the motor is turning.C5103: The control circuit detects motor turning while the motor remains stationary. |
Trouble isolation | – |
Relevant electrical parts | Main motor (M1)CPU board (CPUB)Base board (BASEB) |
Procedure
- Check the connector between M1-BASEB CN17E for proper connection and correct as necessary.
- Check the loading status of the main drive, and correct the error as necessary.
- Check CPUB for proper installation and correct as necessary.
- M1 load check
- Check code: 40
- Multi code: 1, 2
- Control signal: BASEB CN17E-1 to 5
- Location of electrical component: 1-C
- Replace M1.
- Replace CPUB.
- BASEB F18E conduction check
- Replace BASEB.