How Can We Help?
C5103 (bizhub C3320i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C5103: Main motor turning at abnormal timing |
Rank | B |
Trouble detection condition | The control circuit detects motor turning while the motor remains stationary. |
Trouble isolation | – |
Relevant electrical parts | -Main motor (M1) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the connector between M1-BASEB CN17E for proper connection and correct as necessary.
- Check the loading status of the main drive, and correct the error as necessary.
- Check CPUB for proper installation and correct as necessary.
- M1 load check
- Check code: 40
- Multi code: 1, 2
- Control signal: BASEB CN17E-1 to 5
- Location of electrical component: 1-C
- Replace M1. (Part# AA2JM11000)
- Replace CPUB. (Part# AAJRH01005)
- BASEB F18E conduction check
- Replace BASEB. (Part# A93EH02007)
L.3.10.1 (Link to the Field Service Manual)