C5357 (bizhub C3320i)
Contents
| Trouble type | C5357: Machine cooling fan failure to turn | 
| Rank | B | 
| Trouble detection condition | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. | 
| Trouble isolation | – | 
| Relevant electrical parts | -Machine cooling fan (FM1) -CPU board (CPUB) -Base board (BASEB)  | 
Procedure
- Check the connector between FM1-relay CN23-BASEB CN19E for proper connection and correct as necessary.
 - Check the fan for possible overload and correct as necessary.
 - Check CPUB for proper installation and correct as necessary.
 - FM1 load check
- Check code: 42
 - Multi code: 1, 2
 - Control signal: BASEB CN19E-4 (REM), BASEB CN19E-6 (LOCK)
 - Location of electrical component: 9-C
 
 - Replace FM1. (Part# A93EM10000)
 - Replace CPUB. (Part# AAJRH01005)
 - Replace BASEB. (Part# A93EH02007)
 