C5103 (bizhub C650i/C550i/C450i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C5103: Transport motor turning at abnormal timing |
Rank | B |
Trouble detection condition | The control circuit detects motor turning while the motor remains stationary. |
Trouble isolation | – |
Relevant electrical parts | -Transport motor (M1) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the connector between M1-BASEB CN19E for proper connection and correct as necessary.
- Check the loading status of the main drive, and correct the error as necessary.
- Check CPUB for proper installation and correct as necessary.
- M1 load check
- Check code: 40
- Multi code: 1, 2, 3, 4 (bizhub C650i), 1, 3, 4 (bizhub C550i), 1, 2, 4 (bizhub C450i)
- Control signal: BASEB CN19EA-1 to 5
- Location of electrical component: 1-C
- Replace M1. (Part# AA2JM11100)
- Replace CPUB. (C450i Part# AA7RH02P02 / C550i Part# AA7PH02P01 / C650i Part# AA7NH02P03)
- Replace BASEB. (Part# AA7NH02102)
L.3.12.1 (Link to the Field Service Manual)