C5304 (bizhub C658/C558/C458)
Contents
Trouble type | C5304: Fusing power supply cooling fan failure to turn (bizhub C658/C558) |
Rank | B |
Trouble detection condition | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | • Fusing power supply cooling fan (FM12) • MFP board (MFPB) |
Procedure
- Check the connector between FM12-relay CN146-MFPB CN15E for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- FM12 operation check
- Control signal: MFPB CN15E<A>-16 (REM), MFPB CN15E<A>-18 (LOCK)
- Location of electrical component: C658/C558 16-C, C458 20-C
- Replace FM12. (Part# 4139M10000)
- Replace MFPB. (C458 Part# A79MH02102 / C558 or C658 Part # A79JH02102)
NOTICE
- Link to the wiring diagram (bizhub C658/C558/C458)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.17.2 (Link to the Field Service Manual)