How Can We Help?

C5306 (bizhub C658/C558/C458)

You are here:

Contents

Trouble typeC5306: IH coil cooling fans failure to turn (bizhub C658/C558)
RankB
Trouble detection conditionThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical partsIH coil cooling fan (FM7)Expansion control board (EXCB)MFP board (MFPB)

 Procedure

  1. Check the connector between FM7-relay CN77-EXCB CN3 for proper connection and correct as necessary.
  2. Check the fan for possible overload and correct as necessary.
  3. FM7 operation check
    • Control signal: EXCB CN3-1 (REM), EXCB CN3-3 (LOCK)
    • Location of electrical component: 26-T
  4. Replace FM7. (Part# 9313130051)
  5. Replace EXCB. (Part# A79JH00500)
  6. MFPB F6E conduction check
  7. Replace MFPB. (C458 Part# A79MH02102 / C558 or C658 Part # A79JH02102)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.17.3 (Link to the Field Service Manual)

Table of Contents