How Can We Help?

C5351 (bizhub C658/C558/C458)

You are here:

Contents

Trouble typeC5351: Power supply cooling fan’s failure to turn
RankB
Trouble detection conditionThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts• Power supply cooling fan (FM1)
• MFP board (MFPB)

 Procedure

  1. Check the connector between FM1-relay CN26-MFPB CN31E for proper connection and correct as necessary.
  2. Check the fan for possible overload and correct as necessary.
  3. FM1 operation check
    • Control signal: MFPB CN31E<A>-9 (REM), MFPB CN31E<A>-11 (LOCK)
    • Location of electrical component: 23-J
  4. Replace FM1. (Part# 4139M10000)
  5. Replace MFPB. (C458 Part# A79MH02102 / C558 or C658 Part # A79JH02102)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.17.4 (Link to the Field Service Manual)