How Can We Help?

C5351 (bizhub 754e/654e)

You are here:

Contents

Trouble type DC power supply cooling fan’s failure to turn
Trouble code C5351
Rank B
Detection timing The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts • DC power supply cooling fan (FM9)
• DC power supply (DCPU)
• Printer control board (PRCB)

  (2)Procedure

Step Action Control signal Location of electrical components
1 Check the connector between FM9-relay CN333-PRCB CN38 for proper connection and correct as necessary.
2 Check the fan for possible overload and correct as necessary.
3 FM9 operation check PRCB CN38-1 (DRIVE) PRCB CN38-3 (LOCK) 19-K
4 Replace FM9
5 PRCB ICP3 conduction check
6 Replace DCPUDCPU (Part# 100V A2X0R70300)
7 Replace PRCBPRCB (Part# A55VH00105)

Document Information ID D0001104797 Revise ID R000003

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.10.4 (Link to the Field Service Manual)