C5354 (bizhub 754e/654e)

You are here:

Contents

Trouble type Ozone ventilation fan’s failure to turn
Trouble code C5354
Rank B
Detection timing The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts • Ozone ventilation fan motor (FM6)
• Printer control board (PRCB)

  (2)Procedure

Step Action Control signal Location of electrical components
1 Check the connector between FM6-relay CN322-PRCB CN1 for proper connection and correct as necessary.
2 Check the fan for possible overload and correct as necessary.
3 FM6 operation check PRCB CN1-6 (DRIVE) PRCB CN1-8 (LOCK) 7-K
4 Replace FM6
5 Replace PRCBPRCB
StepActionControl signalLocation of electrical components
1Check the connector between FM6-relay CN322-PRCB CN1 for proper connection and correct as necessary.
2Check the fan for possible overload and correct as necessary.
3FM6 operation checkPRCB CN1-6 (DRIVE)PRCB CN1-8 (LOCK)7-K
4Replace FM6 (Part# 9313100072)
5Replace PRCB (Part# A55VH00105)

Document Information ID D0001104798 Revise ID R000003

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.10.5 (Link to the Field Service Manual)