C5351 (bizhub C360i/C300i/C250i)

You are here:

Contents

Trouble typeC5351: PH/power supply cooling fan failure to turn
RankB
Trouble detection conditionThe fan lock signal remains Low for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts• PH/power supply cooling fan (FM1)
• Expansion control board (EXCB)
• CPU board (CPUB)
• Base board (BASEB)

Procedure

  1. Check the connector between FM1-relay CN26-EXCB CN10EX for proper connection and correct as necessary.
  2. Check the fan for possible overload and correct as necessary.
  3. Check the connector between EXCB CN2EX-BASEB CN12E for proper connection and correct as necessary.
  4. Check CPUB for proper installation and correct as necessary.
  5. FM1 load check
    • Check code: 42
    • Multi code: 1
    • Control signal: EXCB CN10EX-6 (REM), EXCB CN10EX-8 (LOCK)
    • Location of electrical component: 10-P
  6. Replace FM1. (Part# A93EM10000)
  7. Replace EXCB. (Part# AA2JH00500)
  8. Replace CPUB. (Part# AA2JH02N06)
  9. Replace BASEB. (Part# AA2JH02005)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.11.2 (Link to the Field Service Manual)