C5351 (bizhub C360i/C300i/C250i)
Contents
Trouble type | C5351: PH/power supply cooling fan failure to turn |
Rank | B |
Trouble detection condition | The fan lock signal remains Low for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | • PH/power supply cooling fan (FM1) • Expansion control board (EXCB) • CPU board (CPUB) • Base board (BASEB) |
Procedure
- Check the connector between FM1-relay CN26-EXCB CN10EX for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- Check the connector between EXCB CN2EX-BASEB CN12E for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- FM1 load check
- Check code: 42
- Multi code: 1
- Control signal: EXCB CN10EX-6 (REM), EXCB CN10EX-8 (LOCK)
- Location of electrical component: 10-P
- Replace FM1. (Part# A93EM10000)
- Replace EXCB. (Part# AA2JH00500)
- Replace CPUB. (Part# AA2JH02N06)
- Replace BASEB. (Part# AA2JH02005)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.11.2 (Link to the Field Service Manual)