C5354 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
| Trouble type | C5354: Ozone ventilation fan failure to turn | 
| Rank | B | 
| Trouble detection condition | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. | 
| Trouble isolation | – | 
| Relevant electrical parts | – Ozone ventilation fan (FM6) – CPU board (CPUB) – Base board (BASEB)  | 
Procedure
- Check the connector between FM6-relay CN322-BASEB CN27E for proper connection and correct as necessary.
 - Check the fan for possible overload and correct as necessary.
 - Check CPUB for proper installation and correct as necessary.
 - FM6 load check
- Check code: 42
 - Multi code: 11, 12
 - Control signal: BASEB CN27E<B>-7 (DRIVE), BASEB CN27E<B>-9 (LOCK)
 - Location of electrical component: 13-C
 
 - Replace FM6.
 - Replace CPUB.
 - BASEB F6E conduction check.
 - Replace BASEB.
 