C5351 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
| Trouble type | C5351: DC power supply cooling fan failure to turn | 
| Rank | B | 
| Trouble detection condition | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. | 
| Trouble isolation | – | 
| Relevant electrical parts | – DC power supply cooling fan (FM9) – DC power supply unit/1 (DCPU/1) – CPU board (CPUB) – Base board (BASEB)  | 
Procedure
- Check the connector between FM9-relay CN333-BASEB CN23E for proper connection and correct as necessary.
 - Check the fan for possible overload and correct as necessary.
 - Check CPUB for proper installation and correct as necessary.
 - FM9 load check
- Check code: 42
 - Multi code: 9, 10
 - Control signal: BASEB CN23E-7 (REM), BASEB CN23E-9 (LOCK)
 - Location of electrical component: 9-K
 
 - Replace FM9.
 - Replace DCPU/1.
 - Replace CPUB.
 - BASEB F6E conduction check.
 - Replace BASEB.
 