C5354 (bizhub 958/808)

You are here:

Contents

Trouble typeC5354: Ozone ventilation fans failure to turn
RankB
Trouble detection conditionThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts• Ozone ventilation fan (FM6)
• MFP board (MFPB)

 Procedure

  1. Check the connector between FM6-relay CN322-MFPB CN27E for proper connection and correct as necessary.
  2. Check the fan for possible overload and correct as necessary.
  3. FM6 operation check
    • Control signal: MFPB CN27E<B>-7 (DRIVE), MFPB CN27E<B>-9 (LOCK)
    • Location of electrical component: 16-C
  4. Replace M6. (Part# 9313100072)
  5. MFPB F6E conduction check
  6. Replace MFPB. (Part# A796H02003)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.11.5 (Link to the Field Service Manual)