C5354 (bizhub C364/C284/C224)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | Ozone fans failure to turn |
Trouble code | C5354 |
Rank | B |
Detection timing | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan remains stationary. |
Trouble isolation | – |
Relevant electrical parts | -Ozone fan (FM13) -Printer control board (PRCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between FM13-relay CN158-PRCB CN23 for proper connection and correct as necessary. | – | – |
2 | Check the fan for possible overload and correct as necessary. | – | – |
3 | FM13 operation check | PRCB CN23-10 (REM)PRCB CN23-12 (LOCK) | 5-C |
4 | Replace FM13 (Part# 9313100072) | – | – |
5 | PRCB ICP19 conduction check | – | – |
6 | Replace PRCB (Part# A161H00108) | – | – |
- Link to the wiring diagram (N.1. bizhub C364/C284/C224)
- Link to the layout drawings for related parts by each trouble code (S.70. C5354)
K3.10.3 (Link to the Field Service Manual)