C5356 (bizhub 287/227)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C5356: Main cooling fan failure to turn |
Rank | B |
Trouble detection condition | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | -Main cooling fan (FM2) -MFP board (MFPB) |
Procedure
- Check the connector between FM2-relay CN21-relay CN27-MFPB CN29E for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- FM2 operation check
- Control signal: MFPB CN29E-6 (REM), MFPB CN29E-8 (LOCK)
- Location of electrical component: 20-C
- Replace FM2. (Part# 9313130051)
- MFPB F12E conduction check
- Replace MFPB. (Part# A7AHH0201D)
NOTICE
- Link to the wiring diagram (bizhub 367/287/227)
K.3.12.3 (Link to the Field Service Manual)