Trouble typeC5359: Reverse cooling fan failure to turn
RankB
Trouble detection conditionThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts-Reverse cooling fan (FM5)
-MFP board (MFPB)

 Procedure

  1. Check the connector between FM5-relay CN88-relay CN20-MFPB CN25E for proper connection and correct as necessary.
  2. Check the fan for possible overload and correct as necessary.
  3. FM5 operation check.
    • Control signal: MFPB CN25E-11 (REM), MFPB CN25E-13 (LOCK)
    • Location of electrical component: 18-C
  4. Replace FM5. (Part# 4556M10000)
  5. Replace MFPB. (Part# A7AHH0201D)