C5359 (bizhub 287/227)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C5359: Reverse cooling fan failure to turn |
Rank | B |
Trouble detection condition | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | -Reverse cooling fan (FM5) -MFP board (MFPB) |
Procedure
- Check the connector between FM5-relay CN88-relay CN20-MFPB CN25E for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- FM5 operation check.
- Control signal: MFPB CN25E-11 (REM), MFPB CN25E-13 (LOCK)
- Location of electrical component: 18-C
- Replace FM5. (Part# 4556M10000)
- Replace MFPB. (Part# A7AHH0201D)
NOTICE
- Link to the wiring diagram (bizhub 367/287/227)
K.3.12.4 (Link to the Field Service Manual)