C5358 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C5358: Fusing power supply cooling fan failure to turn |
Rank | B |
Trouble detection condition | The fan lock signal remains Low for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | – Fusing power supply cooling fan (FM10) – CPU board (CPUB) – Base board (BASEB) |
Procedure
- Check the connector between FM9-relay CN333-BASEB CN23E for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- FM10 load check
- Check code: 42
- Multi code: 27
- Control signal: BASEB CN23E-10 (REM), BASEB CN23E-12 (LOCK)
- Location of electrical component: 10-K
- Replace FM10.
- Replace CPUB.
- BASEB F6E conduction check.
- Replace BASEB.