C5364 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C5364: Fusing edge cooling fan/3 failure to turn |
Rank | B |
Trouble detection condition | The fan lock signal remains Low for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | – Fusing edge cooling fan/3 (FM30) – Paper feed/transport drive board (PFTDB) – CPU board (CPUB) – Base board (BASEB) |
Procedure
- Check the connector between FM30-relay CN833-relay CN166B-PFTDB CN31 for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- FM30 load check
- Check code: 42
- Multi code: 29
- Control signal: PFTDB CN31-7 (REM), PFTDB CN31-8 (LOCK)
- Location of electrical component: 5-P
- Replace FM30.
- PFTDB F22 conduction check.
- Replace PFTDB.
- Replace CPUB.
- Replace BASEB.