C5364 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
| Trouble type | C5364: Fusing edge cooling fan/3 failure to turn | 
| Rank | B | 
| Trouble detection condition | The fan lock signal remains Low for a predetermined continuous period of time while the fan is turning. | 
| Trouble isolation | – | 
| Relevant electrical parts | – Fusing edge cooling fan/3 (FM30) – Paper feed/transport drive board (PFTDB) – CPU board (CPUB) – Base board (BASEB)  | 
Procedure
- Check the connector between FM30-relay CN833-relay CN166B-PFTDB CN31 for proper connection and correct as necessary.
 - Check the fan for possible overload and correct as necessary.
 - Check CPUB for proper installation and correct as necessary.
 - FM30 load check
- Check code: 42
 - Multi code: 29
 - Control signal: PFTDB CN31-7 (REM), PFTDB CN31-8 (LOCK)
 - Location of electrical component: 5-P
 
 - Replace FM30.
 - PFTDB F22 conduction check.
 - Replace PFTDB.
 - Replace CPUB.
 - Replace BASEB.
 