C5365 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
| Trouble type | C5365: Fusing edge cooling fan/4 failure to turn | 
| Rank | B | 
| Trouble detection condition | The fan lock signal remains Low for a predetermined continuous period of time while the fan is turning. | 
| Trouble isolation | – | 
| Relevant electrical parts | – Fusing edge cooling fan/4 (FM31) – Paper feed/transport drive board (PFTDB) – CPU board (CPUB) – Base board (BASEB)  | 
Procedure
- Check the connector between FM31-relay CN834-relay CN166B-PFTDB CN31 for proper connection and correct as necessary.
 - Check the fan for possible overload and correct as necessary.
 - Check CPUB for proper installation and correct as necessary.
 - FM31 load check
- Check code: 42
 - Multi code: 29
 - Control signal: PFTDB CN31-10 (REM), PFTDB CN31-11 (LOCK)
 - Location of electrical component: 5-P
 
 - Replace FM31.
 - PFTDB F22 conduction check.
 - Replace PFTDB.
 - Replace CPUB.
 - Replace BASEB.
 