How Can We Help?

C5360 (bizhub 368e/308e)

You are here:

Contents

Trouble typeC5360: Clean unit fan failure to turn (When CU-101 is installed)
RankB
Trouble detection conditionThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts• Exhaust fan 1 (FM14)
• Exhaust fan 2 (FM15)
• Suction fan (FM16)
• Clean unit drive board (CUDB)
• MFP board (MFPB)

 Procedure

  1. Check the connector between CUDB CN1-MFPB CN32E for proper connection and correct as necessary.
  2. Check the connector between FM14-CUDB CN3, FM15-CUDB CN2, FM16-relay CN183-CUDB CN4 for proper connection and correct as necessary.
  3. Check the fan for possible overload and correct as necessary.
  4. FM14, FM15, FM16 load check
    • Check code: 42
    • Multi code: 4
    • Control signal: CUDB CN3 (FM14), CUDB CN2 (FM15), CUDB CN4 (FM16)
    • Location of electrical component: 14-X
  5. Replace the defective fan. (FM14 / FM15 / FM16)
  6. Replace CUDB.
  7. MFPB ICP14E conduction check
  8. Replace MFPB. (Part# AA6VH02101)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.15.3 (Link to the Field Service Manual)

Table of Contents