C5360 (bizhub 558/458)
Contents
Trouble type | C5360: Clean unit fan’s failure to turn (When CU-102 is installed) |
Rank | B |
Trouble detection condition | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | • Exhaust fan 1 (FM14) • Exhaust fan 2 (FM15) • Clean unit drive board (CUDB) • MFP board (MFPB) |
Procedure
- Check the connector between CUDB CN1-MFPB CN29E for proper connection and correct as necessary.
- Check the connector between FM14-relay CN200-CUDB CN2 for proper connection and correct as necessary.
- Check the connector between FM15-relay CN201-CUDB CN3 for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- FM14 operation check
- Load check: Check code42, Multi code 9
- Control signal: CUDB CN2-1 (REM), CUDB CN2-3 (LOCK)
- Location of electrical component: 15-K
- FM15 operation check
- Load check: Check code42, Multi code 9
- Control signal: CUDB CN3-1 (REM), CUDB CN3-3 (LOCK)
- Location of electrical component: 15-K
- Replace the defective fan. (FM14 / FM15)
- Replace CUDB. (Part# ?)
- MFPB F3E conduction check
- Replace MFPB. (558 Part# A9HGH02102 / 458 Part# A9HHH02102)
NOTICE
- Link to the wiring diagram (bizhub 558/458)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.17.6 (Link to the Field Service Manual)