How Can We Help?

C5360 (bizhub 558/458)

You are here:

Contents

Trouble typeC5360: Clean unit fan’s failure to turn (When CU-102 is installed)
RankB
Trouble detection conditionThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts• Exhaust fan 1 (FM14)
• Exhaust fan 2 (FM15)
• Clean unit drive board (CUDB)
• MFP board (MFPB)

 Procedure

  1. Check the connector between CUDB CN1-MFPB CN29E for proper connection and correct as necessary.
  2. Check the connector between FM14-relay CN200-CUDB CN2 for proper connection and correct as necessary.
  3. Check the connector between FM15-relay CN201-CUDB CN3 for proper connection and correct as necessary.
  4. Check the fan for possible overload and correct as necessary.
  5. FM14 operation check
    • Load check: Check code42, Multi code 9
    • Control signal: CUDB CN2-1 (REM), CUDB CN2-3 (LOCK)
    • Location of electrical component: 15-K
  6. FM15 operation check
    • Load check: Check code42, Multi code 9
    • Control signal: CUDB CN3-1 (REM), CUDB CN3-3 (LOCK)
    • Location of electrical component: 15-K
  7. Replace the defective fan. (FM14 / FM15)
  8. Replace CUDB. (Part# ?)
  9. MFPB F3E conduction check
  10. Replace MFPB. (558 Part# A9HGH02102 / 458 Part# A9HHH02102)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.17.6 (Link to the Field Service Manual)

Table of Contents