C5360 (bizhub 558/458)

You are here:

Contents

Trouble typeC5360: Clean unit fan’s failure to turn (When CU-102 is installed)
RankB
Trouble detection conditionThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts• Exhaust fan 1 (FM14)
• Exhaust fan 2 (FM15)
• Clean unit drive board (CUDB)
• MFP board (MFPB)

 Procedure

  1. Check the connector between CUDB CN1-MFPB CN29E for proper connection and correct as necessary.
  2. Check the connector between FM14-relay CN200-CUDB CN2 for proper connection and correct as necessary.
  3. Check the connector between FM15-relay CN201-CUDB CN3 for proper connection and correct as necessary.
  4. Check the fan for possible overload and correct as necessary.
  5. FM14 operation check
    • Load check: Check code42, Multi code 9
    • Control signal: CUDB CN2-1 (REM), CUDB CN2-3 (LOCK)
    • Location of electrical component: 15-K
  6. FM15 operation check
    • Load check: Check code42, Multi code 9
    • Control signal: CUDB CN3-1 (REM), CUDB CN3-3 (LOCK)
    • Location of electrical component: 15-K
  7. Replace the defective fan. (FM14 / FM15)
  8. Replace CUDB. (Part# ?)
  9. MFPB F3E conduction check
  10. Replace MFPB. (558 Part# A9HGH02102 / 458 Part# A9HHH02102)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.17.6 (Link to the Field Service Manual)