How Can We Help?

C5361 (bizhub 558/458)

You are here:

Contents

Trouble typeC5361: UFP scavenging fan’s failure to turn
RankC
Trouble detection conditionThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts• UFP scavenging fan 1 (FM17)
• UFP scavenging fan 2 (FM18) (bizhub 558 only)
• Expansion control board (EXCB)
• MFP board (MFPB)

 Procedure

  1. Check the connector between FM17-relay CN801-relay CN823-EXCB CN9 for proper connection and correct as necessary.
  2. Check the connector between FM18-relay CN802-relay CN823-EXCB CN9 for proper connection and correct as necessary.
  3. Check the fan for possible overload and correct as necessary.
  4. FM17 operation check
    • Control signal: MFPB CN9-4 (LOCK), MFPB CN9-6 (REM)
    • Location of electrical component: 25-P
  5. FM18 operation check
    • Control signal: MFPB CN9-7 (LOCK), MFPB CN9-8 (REM)
    • Location of electrical component: 24-P
  6. Replace FM17. (Part# 9313100072)
  7. Replace FM18. (Part# 9313100072)
  8. Replace MFPB. (558 Part# A9HGH02102 / 458 Part# A9HHH02102)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.17.7 (Link to the Field Service Manual)

Table of Contents