C5361 (bizhub 558/458)
Contents
Trouble type | C5361: UFP scavenging fan’s failure to turn |
Rank | C |
Trouble detection condition | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | • UFP scavenging fan 1 (FM17) • UFP scavenging fan 2 (FM18) (bizhub 558 only) • Expansion control board (EXCB) • MFP board (MFPB) |
Procedure
- Check the connector between FM17-relay CN801-relay CN823-EXCB CN9 for proper connection and correct as necessary.
- Check the connector between FM18-relay CN802-relay CN823-EXCB CN9 for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- FM17 operation check
- Control signal: MFPB CN9-4 (LOCK), MFPB CN9-6 (REM)
- Location of electrical component: 25-P
- FM18 operation check
- Control signal: MFPB CN9-7 (LOCK), MFPB CN9-8 (REM)
- Location of electrical component: 24-P
- Replace FM17. (Part# 9313100072)
- Replace FM18. (Part# 9313100072)
- Replace MFPB. (558 Part# A9HGH02102 / 458 Part# A9HHH02102)
NOTICE
- Link to the wiring diagram (bizhub 558/458)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.17.7 (Link to the Field Service Manual)