C5360 (bizhub C287/C227)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C5360: Clean unit fan failure to turn (When CU-101 is installed) |
Rank | B |
Trouble detection condition | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | -Exhaust fan/1 (FM14) -Exhaust fan/2 (FM15) -Suction fan (FM16) -Clean unit drive board (CUDB) -MFP board (MFPB) |
Procedure
- Check the connector between CUDB CN1-MFPB CN29E for proper connection and correct as necessary.
- Check the connector between FM14-CUDB CN2, FM15-CUDB CN3, FM16-relay CN81-CUDB CN4 for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- FM14, FM15, FM16 operation check
- Load check: Check code42, Multi code 5
- Control signal: CUDB CN2 (FM14), CUDB CN3 (FM15), CUDB CN4 (FM16)
- Location of electrical component: 12-U (FM16), 12-Y (FM14, FM15)
- Replace the defective fan. (FM14 / FM15 / FM16) (Parts not sold in the U.S., Contact Konica Minolta technical support if this needs to be replaced.)
- Replace CUDB. (Part not sold in the U.S., Contact Konica Minolta technical support if this needs to be replaced.)
- MFPB F16E conduction check
- Replace MFPB. (Part# A797H02118)
NOTICE
- Link to the wiring diagram (bizhub C287/C227)
K.3.12.3 (Link to the Field Service Manual)