C5362 (bizhub 650i/550i/450i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C5362: UFP scavenging fan/Rr failure to turn (bizhub 650i/550i) |
Rank | B |
Trouble detection condition | The fan lock signal remains Low for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | -UFP scavenging fan/Rr (FM18) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the connector between FM18-relay CN802-relay CN5-BASEB CN22E for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- FM18 load check
- Check code: 42
- Multi code: 12
- Control signal: BASEB CN22E-10 (REM), BASEB CN22E-12 (LOCK)
- Location of electrical component: 12-C
- Replace FM18. (Part# A93EM10600)
- Replace CPUB.
650i/550i (Part# AC74H02P03)
450i (Part# AC76H02P02) - Replace BASEB. (Part# AC74H02101)