How Can We Help?

C5370 (bizhub C368/C308/C258)

You are here:

Contents

Trouble typeC5370: Rear side cooling fan failure to turn
RankC
Trouble detection conditionThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts• Rear side cooling fan (FM3)
• MFP board (MFPB)

 Procedure

  1. Check the connector between FM3-relay CN301-MFPB CN13 for proper connection and correct as necessary.
  2. Check the fan for possible overload and correct as necessary.
  3. FM3 operation check
    • Control signal: MFPB CN13-3 (LOCK), MFPB CN13-4 (REM)
    • Location of electrical component: 20-C
  4. Replace FM3. (Part# A0EDM10500)
  5. Replace MFPB. (Part# A7PUH02123)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.16.5 (Link to the Field Service Manual)

Table of Contents