How Can We Help?

C5372 (bizhub 754e/654e)

You are here:

Contents

Trouble type MFP control board CPU temperature failure
Trouble code C5372
Rank C
Detection timing Temperature failure of CPU on the MFP board was detected.
Trouble isolation
Relevant electrical parts • CPU cooling fan (FM104)
• MFP board (MFPB)

  (2)Procedure

Step Action Control signal Location of electrical components
1 Reboot the machine.
2 Check the connector between FM104-MFPB PJ20 for proper connection and correct as necessary.
3 Check the fan for possible overload and correct as necessary.
4 FM104 operation check MFPB PJ20 17-S
5 Replace FM104 Contact Konica Minolta technical support if this needs to be replaced.
6 Replace MFPBMFPB (Part# A55VH02304)

Document Information ID D0001104800 Revise ID R000003

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.10.7 (Link to the Field Service Manual)