Trouble type | C5501: AC signal abnormality (bizhub C450i) |
Rank | C |
Trouble detection condition | The zero cross signal is not input during fusing phase control. |
Trouble isolation | – |
Relevant electrical parts | -Fusing unitDC power supply (DCPU) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the fusing unit for correct installation (whether it is secured in position).
- Check the connector between the fusing unit-relay CN95-BASEB CN4E for proper connection and correct as necessary.
- Check the connector between DCPU CN7-BASEB CN2E for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace the fusing unit. (C650i/C550i Part# AA7NR70200 / C450i Part# AA7RR70700)
- Replace CPUB. (C450i Part# AA7RH02P02 / C550i Part# AA7PH02P01 / C650i Part# AA7NH02P03)
- Replace BASEB. (Part# AA7NH02102)
- Replace DCPU. (bizhub C650i/C550i Part# AA7NR71600 / bizhub C450i Part# AA7RR70200)