C5701 (bizhub C4000i/C3300i)
Contents
Trouble type | C5701: Power supply malfunction |
Rank | C |
Trouble detection condition | A condition is detected in which no power is being supplied to the base board (BASEB). |
Trouble isolation | – |
Relevant electrical parts | • Front door sensor (PS1) • Right door sensor (PS2) • Front door switch (SW2) • Right door switch (SW5) • DC power supply (DCPS) • CPU board (CPUB) • Base board (BASEB) |
Procedure
- Check the connector between PS1, PS2-BASEB CN16E for proper connection and correct as necessary.
- Check the connector between SW2, SW5-relay CN36-DCPS CN3 for proper connection and correct as necessary.
- Check the connector between DCPS CN4-BASEB CN3E for proper connection and correct as necessary.
- Check the connector between DCPS CN6-BASEB CN1E for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace CPUB. (Part# AAJRH01005)
- BASEB F5E conduction check
- Replace BASEB. (Part# AAJRH02005)
- Replace DCPS. (Part# AAJRR70600)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.10.10 (Link to the Field Service Manual)