C6001 (bizhub 658e/558e/458e)
Contents
Trouble type | C6001: DF related configuration error 1 |
Rank | C |
Trouble detection condition | Inconsistency in the configuration with the installed DF is detected on the main body. |
Trouble isolation | – |
Relevant electrical parts | • DF control board (DFCB) • Dual scan image processing board (DSIPB) • MFP board (MFPB) |
Procedure
- Check the type of the installed DF and replace it if it is a wrong one.
- Correct the harness connection between DFCB and DSIPB if faulty.
- Check the connector between DSIPB CN1-MFPB CN24 for proper connection and correct as necessary.
- Replace DFCB. (Part# A782H0010A )
- Replace DSIPB. (Part# A9HGH02A00 )
- MFPB ICP5 conduction check
- Replace MFPB. (658e/558e Part# AA6RH02103 / 458e Part# AA6UH02101)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.18.1 (Link to the Field Service Manual)