C6001 (bizhub 658e/558e/458e)

You are here:

Contents

Trouble typeC6001: DF related configuration error 1
RankC
Trouble detection conditionInconsistency in the configuration with the installed DF is detected on the main body.
Trouble isolation
Relevant electrical parts• DF control board (DFCB)
• Dual scan image processing board (DSIPB)
• MFP board (MFPB)

 Procedure

  1. Check the type of the installed DF and replace it if it is a wrong one.
  2. Correct the harness connection between DFCB and DSIPB if faulty.
  3. Check the connector between DSIPB CN1-MFPB CN24 for proper connection and correct as necessary.
  4. Replace DFCB. (Part# A782H0010A )
  5. Replace DSIPB. (Part# A9HGH02A00 )
  6. MFPB ICP5 conduction check
  7. Replace MFPB. (658e/558e Part# AA6RH02103 / 458e Part# AA6UH02101)