How Can We Help?
C6001 (bizhub C3320i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C6001: DF related configuration error 1 |
Rank | C |
Trouble detection condition | Inconsistency in the configuration with the installed DF is detected on the main body. |
Trouble isolation | – |
Relevant electrical parts | -DF control board (DFCB) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the type of the installed DF and replace it if it is a wrong one.
- Check to see the [Service mode] -> [System 2] -> [ADF Settings] is correct. It corrects, when a model is different.
- Check the connector between DFCB CN9-BASEB CN6E for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace DFCB. (Part# A93EH00901)
- Replace CPUB. (Part# AAJRH01005)
- Replace BASEB. (Part# A93EH02007)
L.3.11.1 (Link to the Field Service Manual)