C6001 (bizhub C554/C454)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | DF related configuration error 1 |
Trouble code | C6001 |
Rank | C |
Detection timing | Inconsistency in the configuration with the installed DF is detected on the main body. |
Trouble isolation | – |
Relevant electrical parts | -DF control board (DFCB) -Dual scan image processing board (DSIPB) -MFP board (MFPB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the type of the installed DF and replace it if it is a wrong one. | – | – |
2 | Check to see if the correct firmware is installed and rewrite with the correct one as necessary. | – | – |
3 | Correct the harness connection between DFCB and DSIPB if faulty. | – | – |
4 | Correct the harness connection between DSIPB and MFPB if faulty. | – | – |
5 | Replace DFCB (Part# A3CKH00102) | – | – |
6 | Replace DSIPB (Part# A161H02A00) | – | – |
7 | Replace MFPB (Part# A2XKH02004) | – | – |
- Link to the layout drawings for related parts by each trouble code (S.106. C6001)
K3.11.1 (Link to the Field Service Manual)