Trouble typeDF related configuration error 2
Trouble codeC6002
RankC
Detection timingInconsistency in the configuration with the installed DF is detected on the DF.
Trouble isolation
Relevant electrical parts• DF control board (DFCB)
• Dual scan image processing board (DSIPB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the type of the installed DF and replace it if it is a wrong one.
2Correct the harness connection between DFCB and DSIPB if faulty.
3Check the connectors of the dual scan image processing board (DSIPB) for proper connection, and correct as necessary. (Direction of the point of contact and connection state of the flat cable in particular)
  • Link to the layout drawings for related parts by each trouble code (S.78. C6002)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.11.2 (Link to the Field Service Manual)