How Can We Help?

C6102 (bizhub 287/227)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC6102: Drive system home sensor malfunction
RankB
Trouble detection condition-The scanner home sensor (PS105) is unable to detect the scanner located at its home position.
-The scanner home sensor (PS105) is unable to detect a scanner even when the scanner motor (M101) has been driven to move the scanner over the maximum travelling distance.
-The scanner home sensor (PS105) detects the scanner when the scanner has moved the maximum travelling distance from the position, at which it blocks the scanner home sensor (PS105).
Trouble isolationScanner
Relevant electrical parts-Scanner home sensor (PS105)
-Scanner motor (M101)
-MFP board (MFPB)

 Procedure

  1. Correct or change the scanner drive (pulley, gear, belt) if it is faulty.
  2. Correct the scanner motor set screw if loose.
  3. Adjust [Image Position: Leading Edge] and [Sub Scan Zoom Adj.].
  4. Check the connector between M101-relay CN6IR-MFPB CN26E for proper connection and correct as necessary.
  5. Check the connector between PS105-MFPB CN27E for proper connection and correct as necessary.
  6. PS105 I/O check, sensor check
    • Control signal: MFPB CN27E-15 (ON)
    • Location of electrical component: 5-V
  7. M101 operation check
    • Control signal: MFPB CN26E-1 to 4
    • Location of electrical component: 6-W
  8. Replace MFPB. (Part# A7AHH0201D)

NOTICE

K.3.13.1 (Link to the Field Service Manual)