C6105 (bizhub C364/C284/C224)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | Back side cleaning home sensor abnormality (normal) | |
Trouble code | C6105 | |
Rank | B | |
Detection timing | <When DF-701 is installed> At the time of operation other than the initial operation, the CIS cleaning sensor (PS7) error is detected. | |
Trouble isolation | Scanner | |
Relevant electrical parts | -CIS cleaning sensor (PS7) -CIS cleaning motor (M5) -DF control board (DFCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check if the opening and closing guide is firmly closed. | – | – |
2 | Check the connector between M5-DFCB J9 for proper connection, and correct as necessary. | – | – |
3 | Check the connector of M5 for proper drive coupling, and correct as necessary. | – | – |
4 | Check the connector between PS7-DFCB J13 for proper connection, and correct as necessary. | – | – |
5 | PS7 I/O check, sensor check | DRCB J13-3 (ON) | DF-701 1-G |
6 | M5 operation check | DRCB J9-1 to 4 | DF-701 6-G |
7 | Replace M5 (Part# A3CEPP4A01) | – | – |
8 | Replace DFCB (Part# A3CEPP4900) | – | – |
- Link to the wiring diagram (N.2.1 DF-701)
- Link to the layout drawings for related parts by each trouble code (S.78. C6104, C6105)
K3.11.4 (Link to the Field Service Manual)