C6751 (bizhub 754e/654e)
Contents
Trouble type | CCD clamp/gain adjustment failure |
Trouble code | C6751 |
Rank | B |
Detection timing | • The adjustment value is 0 or 255 during a CCD clamp adjustment. • The peak value of the output data is 64 or less during a CCD gain adjustment. |
Trouble isolation | Scanner |
Relevant electrical parts | • LED exposure unit (LA201) • CCD board (CCDB) • MFP board (MFPB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Correct the harness connection between CCDB and MFPB if faulty. | – | – |
2 | Check for possible extraneous light and correct as necessary. | – | – |
3 | Clean the lens, mirrors, CCD surface, and shading sheet if dirty | – | – |
4 | Correct reflective mirror of the scanner if faulty, or change scanner mirror. | – | – |
5 | Replace the CCD unitCCDB (Part# A2X0R72111) | – | – |
6 | Replace MFPBMFPB (Part# A55VH02304) | – | – |
- Link to the layout drawings for related parts by each trouble code (S.95. C6751)
Document Information ID D0001104807 Revise ID R000003
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.11.6 (Link to the Field Service Manual)