How Can We Help?

C6753 (bizhub 754e/654e)

You are here:

Contents

Trouble type ASIC clock input error (back side)
Trouble code C6753
Rank C
Detection timing When starting the machine, verification on reading and writing the predetermined value for image processing ASIC on dual scan image processing board was conducted, and verification failure was detected.
Trouble isolation
Relevant electrical parts• Dual scan image processing board (DSIPB)
• CIS module (CIS)
• MFP board (MFPB)

  (2)Procedure

Step Action Control signal Location of electrical components
1 Correct the harness connection between DF and DSIPB if faulty.
2 Correct the harness connection between DSIPB and MFPB if faulty.
3 Replace CISCIS (Part# A2X0R70M00)
4 Replace DSIPBDSIPB (Part# A5C1H02A01)
5 Replace MFPBMFPB (Part# A55VH02304)
  • Link to the layout drawings for related parts by each trouble code (S.96. C6753)

Document Information ID D0001104809 Revise ID R000003

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.11.8 (Link to the Field Service Manual)