How Can We Help?

C6754 (bizhub 754e/654e)

You are here:

Contents

Trouble type CIS clamp adjustment failure
Trouble code C6754
Rank B
Detection timing After the gain adjustment is performed at the start-up, the CIS clamp adjustment value is too high or too low.
Trouble isolation Scanner
Relevant electrical parts• CIS module (CIS)
• Dual scan image processing board (DSIPB)
• DF power supply (DFPU)
• MFP board (MFPB)

  (2)Procedure

Step Action Control signal Location of electrical components
1 Correct the harness connection between CIS and DSIPB if faulty.
2 Correct the harness connection between CIS and DFPU if faulty.
3 Check for possible extraneous light and correct as necessary.
4 Clean the back side reading glass and the shading sheet if dirty.
5 Replace CISCIS (Part# A2X0R70M00)
6 Replace DSIPBDSIPB (Part# A5C1H02A01)
7 Replace DFPUDFPU (Part# A3CKH00200)
8 Replace MFPBMFPB (Part# A55VH02304)

Document Information ID D0001104810 Revise ID R000003

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.11.9 (Link to the Field Service Manual)

Table of Contents