C6753 (bizhub C364/C284/C224)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | ASIC clock input error (back side) | |
Trouble code | C6753 | |
Rank | C | |
Detection timing | <When DF-701 is installed> When starting the machine, verification on reading and writing the predetermined value for image processing ASIC on dual scan image processing board (DSIPB) was conducted, and verification failure was detected. | |
Trouble isolation | – | |
Relevant electrical parts | -CIS moduleCIS -Dual scan image processing board (DSIPB) -MFP board (MFPB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Correct the harness connection between DF and DSIPB if faulty. | – | – |
2 | Correct the harness connection between DSIPB and MFPB if faulty. | – | – |
3 | Replace CIS (Part# A3CEM70000) | – | – |
4 | Replace DSIPB (Part# A161H02A00) | – | – |
5 | Replace MFPB (C364/C284 Part# A161H02104 / C224 Part# A4FMH02208) | – | – |
- Link to the layout drawings for related parts by each trouble code (S.82. C6753)
K3.11.8 (Link to the Field Service Manual)