How Can We Help?

C6901, C6902, C6903, C6911, C6912, C6913 (bizhub C750i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC6901: DSC board mount failure 1 (When SC-509 is installed)

C6902: DSC board bus check NG1-1 (When SC-509 is installed)

C6903: DSC board bus check NG1-2 (When SC-509 is installed)

C6911: DSC board mount failure 2 (When SC-509 is installed)

C6912: DSC board bus check NG2-1 (When SC-509 is installed)

C6913: DSC board bus check NG2-2 (When SC-509 is installed)
RankC
Trouble detection conditionC6901: When MFP detects that DSC board/1 (front side) is not properly installed.

C6902, C6903: When DSC bus check (front side) detects an error.C6911: When MFP detects that DSC board/1 (back side) is not properly installed.

C6912, C6913: When DSC bus check (back side) detects an error.
Trouble isolation
Relevant electrical parts-DSC board/1 (DSCB/1; SC-509)
-CPU board (CPUB)

Procedure

  1. Check the connector between DSCB/1 CN1-CPUB CN9 for proper connection and correct as necessary.
  2. Replace DSCB/1. (Part# AA2JH02900)
  3. Replace CPUB. (Part# ACKNH02P03