How Can We Help?
C6F01, C6F02, C6F03, C6F04, C6F05, C6F06, C6F07, C6F08, C6F09, C6F0A, C6FDC, C6FDD (bizhub C750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C6F01: Scanner sequence trouble 1 C6F02: Scanner sequence trouble 2 C6F03: Scanner sequence trouble 3 C6F04: Scanner sequence trouble 4 C6F05: Scanner sequence trouble 5 C6F06: Scanner sequence trouble 6 C6F07: Scanner sequence trouble 7 C6F08: Scanner sequence trouble 8 C6F09: Scanner sequence trouble 9 C6F0A: Scanner sequence trouble 10 C6FDC: Scanner sequence trouble DC C6FDD: Scanner sequence trouble DD |
Rank | C6F01 to C6F0A: C C6FDC, C6FDD: B |
Trouble detection condition | The original transport interval becomes shorter than the predetermined value due to an original transport control error in original reading in DF. |
Trouble isolation | Scanner |
Relevant electrical parts | -CPU board (CPUB) -Base board (BASEB) -DF control board (DFCB) |
Procedure
- Correct the harness connection between main body and DF if faulty.
- Check CPUB for proper installation and correct as necessary.
- Replace DFCB. (Part# AAMPH00105)
- Replace CPUB. (Part# ACKNH02P03)
- Replace BASEB. (Part# ACKNH02101)