Trouble typeC6911: DSC board mount failure 2 (When SC-508 is installed)
RankC
Trouble detection conditionWhen MFP detects that DSC board/2 (back side) is not properly installed.
Trouble isolation
Relevant electrical parts• DSC board/2 (DSCB/2; SC-508)
• Dual scan image processing board (DSIPB)
• MFP board (MFPB)

 Procedure

  1. Correct the harness connection of DSCB/2 if faulty.
  2. Correct the harness connection of DSIPB if faulty.
  3. Replace DSCB/2. (Part# N/A)
  4. Replace DSIPB. (Part# A9HGH02A00)
  5. Replace MFPB. (658e/558e Part# AA6RH02103 / 458e Part# AA6UH02101)