C6912 (bizhub 658e/558e/458e)
Contents
Trouble type | C6912: DSC board bus check NG2-1 (When SC-508 is installed) |
Rank | C |
Trouble detection condition | When DSC bus check (back side) detects an error. |
Trouble isolation | – |
Relevant electrical parts | • DSC board/2 (DSCB/2; SC-508) • Dual scan image processing board (DSIPB) • MFP board (MFPB) |
Procedure
- Correct the harness connection of DSCB/2 if faulty.
- Correct the harness connection of DSIPB if faulty.
- Replace DSCB/2. (Part# N/A)
- Replace DSIPB. (Part# A9HGH02A00)
- Replace MFPB. (658e/558e Part# AA6RH02103 / 458e Part# AA6UH02101)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.18.12 (Link to the Field Service Manual)