How Can We Help?

C6913 (bizhub 658e/558e/458e)

You are here:

Contents

Trouble type C6913: DSC board bus check NG2-2 (When SC-508 is installed)
RankC
Trouble detection conditionWhen DSC bus check (back side) detects an error.
Trouble isolation
Relevant electrical parts• DSC board/2 (DSCB/2; SC-508) 
• Dual scan image processing board (DSIPB) 
• MFP board (MFPB)

 Procedure

  1. Correct the harness connection of DSCB/2 if faulty.
  2. Correct the harness connection of DSIPB if faulty.
  3. Replace DSCB/2. (Part# N/A)
  4. Replace DSIPB. (Part# A9HGH02A00)
  5. Replace MFPB. (658e/558e Part# AA6RH02103 / 458e Part# AA6UH02101)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.18.12 (Link to the Field Service Manual)