How Can We Help?

C6911 (bizhub 958/808)

You are here:

Contents

Trouble typeC6911: DSC board mount failure 2
RankC
Trouble detection conditionWhen MFP detects that DSC board/2 (back side) is not properly installed.
Trouble isolation
Relevant electrical parts• DSC board/2 (DSCB/2; SC-508)
• Dual scan image processing board (DSIPB)
• MFP board (MFPB)

 Procedure

  1. Correct the harness connection of DSCB/2 if faulty.
  2. Correct the harness connection of DSIPB if faulty.
  3. Replace DSCB/2. (Part# N/A) – No Parts Manual
  4. Replace DSIPB. (Part# A796H02A00)
  5. Replace MFPB. (Part# A796H02003)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.12.12 (Link to the Field Service Manual)