C6912 (bizhub 958/808)
Contents
Trouble type | C6912: DSC Bus check NG2-1 |
Rank | C |
Trouble detection condition | When DSC bus check (back side) detects an error. |
Trouble isolation | – |
Relevant electrical parts | • DSC board/2 (DSCB/2; SC-508) • Dual scan image processing board (DSIPB) • MFP board (MFPB) |
Procedure
- Correct the harness connection of DSCB/2 if faulty.
- Correct the harness connection of DSIPB if faulty.
- Replace DSCB/2. (Part# N/A) – No Parts Manual
- Replace DSIPB. (Part# A796H02A00)
- Replace MFPB. (Part# A796H02003)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.12.12 (Link to the Field Service Manual)