C6912 (bizhub C360i/C300i/C250i)
Contents
Trouble type | C6912: DSC board bus check NG2-1 (When SC-509 is installed) |
Rank | C |
Trouble detection condition | When DSC bus check (back side) detects an error. |
Trouble isolation | – |
Relevant electrical parts | • DSC board/1 (DSCB/1; SC-509) • CPU board (CPUB) |
Procedure
- Check the connector between DSCB/1 CN1-CPUB CN9 for proper connection and correct as necessary.
- Replace DSCB/1 (Part# AA2JH02900)
- Replace CPUB. (Part# AA2JH02N06)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.12.11 (Link to the Field Service Manual)