C6912 (bizhub C360i/C300i/C250i)

You are here:

Contents

Trouble typeC6912: DSC board bus check NG2-1 (When SC-509 is installed)
RankC
Trouble detection conditionWhen DSC bus check (back side) detects an error.
Trouble isolation
Relevant electrical parts• DSC board/1 (DSCB/1; SC-509) 
• CPU board (CPUB)

Procedure

  1. Check the connector between DSCB/1 CN1-CPUB CN9 for proper connection and correct as necessary.
  2. Replace DSCB/1 (Part# AA2JH02900)
  3. Replace CPUB. (Part# AA2JH02N06)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.