C6F01,C6F02,C6F03,C6F04,C6F05,C6F06,C6F07,C6F08,C6F09,C6F0A,C6FDC,C6FDD (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | – C6F01: Scanner sequence trouble 1 – C6F02: Scanner sequence trouble 2 – C6F03: Scanner sequence trouble 3 – C6F04: Scanner sequence trouble 4 – C6F05: Scanner sequence trouble 5 – C6F06: Scanner sequence trouble 6 – C6F07: Scanner sequence trouble 7 – C6F08: Scanner sequence trouble 8 – C6F09: Scanner sequence trouble 9 – C6F0A: Scanner sequence trouble 10 – C6FDC: Scanner sequence trouble D – CC6FDD: Scanner sequence trouble DD |
Rank | – C6F01 to C6F0A: C – C6FDC, C6FDD: B |
Trouble detection condition | The original transport interval becomes shorter than the predetermined value due to an original transport control error in original reading in DF. |
Trouble isolation | Scanner |
Relevant electrical parts | – CPU board (CPUB) – Base board (BASEB) – DF control board (DFCB) |
Procedure
- Correct the harness connection between main body and DF if faulty.
- Check CPUB for proper installation and correct as necessary.
- Replace DFCB.
- Replace CPUB.
- Replace BASEB.