How Can We Help?

C8101 (bizhub 958/808)

You are here:

Contents

Trouble typeC8101: Before reading pressure welding alienation mechanism trouble
RankB
Trouble detection condition• During a pressure motion being performed, the before read sensor (PS6) output does not change from H to L.
• During a retraction motion being performed, the before read sensor (PS6) output does not change from L to H.
Trouble isolationDF
Relevant electrical parts• Reading roller pressure/retraction motor (M6)
• Before read sensor (PS6)
• DF control board (DFCB)

 Procedure

  1. Check the connector between M6-relay CN118-DFCB CN4 for proper connection and correct as necessary.
  2. Check the connector of M6 for proper drive coupling and correct as necessary.
  3. Check the connector between PS6-relay CN120-DFCB CN11 for proper connection and correct as necessary.
  4. PS6 I/O check, sensor check
    • Control signal: DFCB CN11-2 (ON)
    • Location of electrical component: DF 1-C
  5. M6 operation check
    • Control signal: DFCB CN4-1 to 2
    • Location of electrical component: DF 10-C
  6. Replace M6. (Part# A782R70100 )
  7. DFCB ICP9 conduction check.
  8. Replace DFCB. (Part# A782H0010A)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.13.1 (Link to the Field Service Manual)

Table of Contents