Trouble typeC7112: Tray 2 lift-up motor failure
RankC
Trouble detection conditionAfter starting the motor, an error is detected for the malfunction detection signal.
Trouble isolationTray 2
Relevant electrical partsTray 2 lift-up motor (M13)Base board (BASEB)

Procedure

  1. Check the connector between M13-relay CN181-BASEB CN25E for proper connection and correct as necessary.
  2. Check the connector of M13 for proper drive coupling and correct as necessary.
  3. M13 conduction check.
    • Control signal: BASEB CN25E-10 (REM)
    • Location of electrical component: 18-K
  4. Replace M13. (Part# 9J06M10300)
  5. Replace BASEB. (Part# AC77H02101)