C7134 (bizhub C360i/C300i/C250i)

You are here:

Contents

Trouble typeC7134: Toner cartridge motor/YM failure
RankC
Trouble detection conditionAfter starting the motor, an error is detected for the malfunction detection signal.
Trouble isolation
Relevant electrical parts• Toner cartridge motor/YM (M10)
• Expansion control board (EXCB)

Procedure

  1. Check the connector between M10-EXCB CN11EX for proper connection and correct as necessary.
  2. Check the connector of M10 for proper drive coupling and correct as necessary.
  3. M10 conduction check.
    • Control signal: EXCB CN11EX-5 to 8
    • Location of electrical component: 4-P
  4. Replace M10. (Part# A7PUM10700)
  5. Replace EXCB. (Part# AA2JH00500)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.13.8 (Link to the Field Service Manual)